Gamer.Site Web Search

  1. Ad

    related to: boiler hot water temperature setting guide

Search results

  1. Results From The WOW.Com Content Network
  2. Thermostatic radiator valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_radiator_valve

    A thermostatic radiator valve on position 2 (15–17 °C) Installed thermostatic radiator valve with the adjustment wheel removed. A thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator.

  3. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    Water heating is a heat transfer process that uses an energy source to heat water above its initial temperature. Typical domestic uses of hot water include cooking, cleaning, bathing, and space heating. In industry, hot water and water heated to steam have many uses. Domestically, water is traditionally heated in vessels known as water heaters ...

  4. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    A hot water reset control loop measures the outside air temperature; this information is used to estimate demand or heating load as the outdoor temperature varies. The supply hot water temperature is modulated up and down range in an inverse linear ratio to outside air temperature. The typical range for conventional boilers is to vary the ...

  5. Thermostat - Wikipedia

    en.wikipedia.org/wiki/Thermostat

    A thermostat, when set to "cool", will only turn on when the ambient temperature of the surrounding room is above the set temperature. Thus, if the controlled space has a temperature normally above the desired setting when the heating/cooling system is off, it would be wise to keep the thermostat set to "cool", despite what the temperature is ...

  6. Aquastat - Wikipedia

    en.wikipedia.org/wiki/Aquastat

    Aquastat. An aquastat is a device used in hydronic heating systems for controlling water temperature. [1][2] To prevent the boiler from firing too frequently, aquastats have a high limit temperature and a low limit. If the thermostat is calling for heat, the boiler will fire until the high limit is reached, then shut off (even if the thermostat ...

  7. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Temperature control valves are used to blend hot supply water into the return to avoid thermal shock or condensation inside of the boiler. The lower the return temperature to the boiler the more likely it will be in condensing mode. If the return temperature is kept below approximately 55 °C (131 °F), the boiler should still be in condensing ...

  8. Tankless water heating - Wikipedia

    en.wikipedia.org/wiki/Tankless_water_heating

    Gas water heaters have an exhaust vent or one to two exhaust pipes on the top, and still require electric power for electronics, sensing and ignition. A three-phase, 21 kW, 400-volt tankless water heater in Europe, with new European color coding for three-phase power. There are also heaters that use several single-phase circuits instead.

  9. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    The ASME Boiler & Pressure Vessel Code (BPVC) is an American Society of Mechanical Engineers (ASME) standard that regulates the design and construction of boilers and pressure vessels. [1] The document is written and maintained by volunteers chosen for their technical expertise . [2] The ASME works as an accreditation body and entitles ...

  1. Ad

    related to: boiler hot water temperature setting guide