Search results
Results From The WOW.Com Content Network
Normal boiling points for pure substances, bubble and dew points for zeotropic blends, or normal boiling point and azeotropic temperature for the azeotropic blends, at 101,325 Pa (1 atmosphere) and in degrees Celsius; Critical temperature in degrees Celsius; Absolute critical pressure in kilopascals
Vapour-compression refrigeration or vapor-compression refrigeration system ( VCRS ), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles. It is also used in domestic and commercial refrigerators, large-scale warehouses ...
Refrigerant. A refrigerant is a working fluid used in the refrigeration cycle of air conditioning systems and heat pumps where in most cases they undergo a repeated phase transition from a liquid to a gas and back again. Refrigerants are heavily regulated due to their toxicity, flammability and the contribution of CFC and HCFC refrigerants to ...
Values are given in terms of temperature necessary to reach the specified pressure. Valid results within the quoted ranges from most equations are included in the table for comparison. A conversion factor is included into the original first coefficients of the equations to provide the pressure in pascals (CR2: 5.006, SMI: -0.875).
R-407A. R-407A is a mixture of gasses used as a refrigerant. It is a zeotropic blend of difluoromethane (HFC-32), pentafluoroethane (HFC-125) and 1,1,1,2-tetrafluoroethane (HFC-134a). [1] R-407A was developed as a close match to R-22 's capacities and flow rates, making it well suited as an energy efficient retrofit for R-22 in medium and low ...
A cascade refrigeration cycle is a multi-stage thermodynamic cycle. An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1] In a cascade refrigeration system, two or more vapor-compression cycles with different refrigerants are used.
A chiller is a machine that removes heat from a liquid coolant via a vapor-compression, adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream (such as air or process water). As a necessary by-product, refrigeration creates waste heat ...
R-407C. R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1]