Gamer.Site Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    Hot water reset, also called outdoor reset ( ODR ), is an energy-saving automatic control algorithm for heating boilers that are typically fired with fuel oil or natural gas. A hot water reset control loop measures the outside air temperature; this information is used to estimate demand or heating load as the outdoor temperature varies.

  3. Glossary of boiler terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_boiler_terms

    A generic term for water-tube boilers of the Yarrow pattern. In Royal Navy practice, a reference to the specific Admiralty example of this. Throatplate a plate forming the lower front of the outer firebox of a locomotive boiler, below the barrel. Top-feed in locomotive boilers, a feed water check valve placed on the top of the boiler drum. This ...

  4. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    Water heating is a heat transfer process that uses an energy source to heat water above its initial temperature. Typical domestic uses of hot water include cooking, cleaning, bathing, and space heating. In industry, hot water and water heated to steam have many uses. Domestically, water is traditionally heated in vessels known as water heaters ...

  5. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    The ASME Boiler & Pressure Vessel Code (BPVC) is an American Society of Mechanical Engineers (ASME) standard that regulates the design and construction of boilers and pressure vessels. [1] The document is written and maintained by volunteers chosen for their technical expertise . [2] The ASME works as an accreditation body and entitles ...

  6. Fire-tube boiler - Wikipedia

    en.wikipedia.org/wiki/Fire-tube_boiler

    By using non-condensing modulating boiler. By setting the controls (thermostats or controller with temperature sensors) with greater temperature differentials between STOP and START. At Non-Condensing Boilers make provisions so that minimum return water temperature of 130 °F (54 °C) to 150 °F (66 °C) to the boiler to avoid fireside corrosion.

  7. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Condensing boiler. Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the ...

  8. Aquastat - Wikipedia

    en.wikipedia.org/wiki/Aquastat

    Aquastat. An aquastat is a device used in hydronic heating systems for controlling water temperature. [1] [2] To prevent the boiler from firing too frequently, aquastats have a high limit temperature and a low limit. If the thermostat is calling for heat, the boiler will fire until the high limit is reached, then shut off (even if the ...

  9. Back boiler - Wikipedia

    en.wikipedia.org/wiki/Back_boiler

    Back boiler. A back boiler is a device which is fitted to a residential heating stove or open fireplace to enable it to provide both room heat and domestic hot water or central heating. The device is water filled heat exchanger enclosed at the rear of the burning chamber, with a hot water output at the top of the chamber and a cold water feed ...