  2. Absorption refrigerator - Wikipedia

    en.wikipedia.org/wiki/Absorption_refrigerator

    An absorption refrigerator is a refrigerator that uses a heat source to provide the energy needed to drive the cooling process. Solar energy, burning a fossil fuel, waste heat from factories, and district heating systems are examples of convenient heat sources that can be used. An absorption refrigerator uses two coolants: the first coolant ...

  3. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    Coefficient of performance. The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.

  4. Free cooling - Wikipedia

    en.wikipedia.org/wiki/Free_cooling

    Free cooling is an economical method of using low external air temperatures to assist in chilling water, which can then be used for industrial processes, or air conditioning systems. The chilled water can either be used immediately or be stored for the short- or long-term. When outdoor temperatures are lower relative to indoor temperatures ...

  5. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    Vapour-compression refrigeration or vapor-compression refrigeration system ( VCRS ), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles. It is also used in domestic and commercial refrigerators, large-scale warehouses ...

  6. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    The energy efficiency ratio (EER) of a particular cooling device is the ratio of output cooling energy (in BTUs) to input electrical energy (in watt-hours) at a given operating point. EER is generally calculated using a 95 °F (35 °C) outside temperature and an inside (actually return-air) temperature of 80 °F (27 °C) and 50% relative humidity.

  7. Cooling load temperature difference calculation method ...

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The equations for the use of the data retrieved from these tables are very simple. Q= heat gain, usually heat gain per unit time. A= surface area. U= Overall heat transfer coefficient. CLTD= cooling load temperature difference. SCL= solar cooling load factor. CLF= cooling load factor. SC= shading coefficient.

  8. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    Air conditioning, often abbreviated as A/C (US) or air con (UK), [1] is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling the humidity of internal air. Air conditioning can be achieved using a mechanical ...

  9. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    In design, operative temperature can be defined as the average of the mean radiant and ambient air temperatures, weighted by their respective heat transfer coefficients. [6] The instrument used for assessing environmental thermal comfort in terms of operative temperature is called a eupatheoscope and was invented by A. F. Dufton in 1929. [7]