Search results
Results From The WOW.Com Content Network
The equations for the use of the data retrieved from these tables are very simple. Q= heat gain, usually heat gain per unit time. A= surface area. U= Overall heat transfer coefficient. CLTD= cooling load temperature difference. SCL= solar cooling load factor. CLF= cooling load factor. SC= shading coefficient.
IEC 60642 Piezoelectric ceramic resonator units. IEC 60644 Specification for high-voltage fuse-links for motor circuit applications. IEC 60645 Electroacoustics – Audiometric equipment. IEC 60648 Method of test for coefficients of friction of plastic film and sheeting for use as electrical insulation.
An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum operating temperature to the maximum operating temperature (or peak operating ...
In thermal engineering, Heisler charts are a graphical analysis tool for the evaluation of heat transfer in transient, one-dimensional conduction. [1] They are a set of two charts per included geometry introduced in 1947 by M. P. Heisler [2] which were supplemented by a third chart per geometry in 1961 by H. Gröber.
The Steinhart–Hart equation is a model relating the varying electrical resistance of a semiconductor to its varying temperatures. The equation is. where. is the temperature (in kelvins ), is the resistance at (in ohms), , , and are the Steinhart–Hart coefficients, which are characteristics specific to the bulk semiconductor material over a ...
Junction temperature, short for transistor junction temperature, [1] is the highest operating temperature of the actual semiconductor in an electronic device. In operation, it is higher than case temperature and the temperature of the part's exterior. The difference is equal to the amount of heat transferred from the junction to case multiplied ...
EN 1: Flued oil stoves with vaporizing burners. EN 2: Classification of fires. EN 3: Portable fire extinguishers. EN 14: Dimensions of bed blankets. EN 19: Industrial valves – Marking of metallic valves. EN 20: Wood preservatives. EN 26: Gas-fired instantaneous water heaters for the production of domestic hot water.
To calculate the actual efficiency of an engine requires the energy density of the fuel being used. Different fuels have different energy densities defined by the fuel's heating value. The lower heating value (LHV) is used for internal-combustion-engine-efficiency calculations because the heat at temperatures below 150 °C (300 °F) cannot be ...