Gamer.Site Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    A heat detector is a fire alarm device designed to respond when the convected thermal energy of a fire increases the temperature of a heat sensitive element. The thermal mass and conductivity of the element regulate the rate flow of heat into the element. All heat detectors have this thermal lag. Heat detectors have two main classifications of ...

  3. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly ...

  4. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    Hot water reset. Hot water reset, also called outdoor reset ( ODR ), is an energy-saving automatic control algorithm for heating boilers that are typically fired with fuel oil or natural gas. A hot water reset control loop measures the outside air temperature; this information is used to estimate demand or heating load as the outdoor ...

  5. U.S. house fire facts and statistics in 2024 - AOL

    www.aol.com/finance/u-house-fire-facts...

    In 2022, one fatal house fire occurred every three hours and 14 minutes while one home fire injury occurred every 53 minutes. (NFPA) Home fires in 2022 resulted in 2,710 civilian deaths. (NFPA) In ...

  6. Backdraft - Wikipedia

    en.wikipedia.org/wiki/Backdraft

    Backdraft. A backdraft ( North American English) or backdraught ( British English) [ 1] or smoke explosion is the abrupt burning of superheated gases in a fire caused when oxygen rapidly enters a hot, oxygen-depleted environment; for example, when a window or door to an enclosed space is opened or broken. Backdrafts are typically seen as a ...

  7. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    For example, a conventional heat pump system used to heat a building in Montana's −57 °C (−70 °F) low temperature or cool a building in the highest temperature ever recorded in the US—57 °C (134 °F) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air ...

  8. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...

  9. Flame detector - Wikipedia

    en.wikipedia.org/wiki/Flame_detector

    Flame detector. A flame detector is a sensor designed to detect and respond to the presence of a flame or fire, allowing flame detection. Responses to a detected flame depend on the installation, but can include sounding an alarm, deactivating a fuel line (such as a propane or a natural gas line), and activating a fire suppression system.