Insulation system. The electrical insulation system for wires used in generators, electric motors, transformers, and other wire-wound electrical components is divided into different classes by temperature and temperature rise. The electrical insulation system is sometimes referred to as insulation class or thermal classification.
The above table shows that the surface temperature of a piece of electrical equipment with a temperature classification of T3 will not rise above 200 °C. The surface of a high pressure steam pipe may be above the autoignition temperature of some fuel-air mixtures.
In the USSR, per GOST 2582-72 with class N insulation, the maximum temperatures allowed for DC motors were 160 °C for the armature, 180 °C for the stator, and 105 °C for the collector. The one-hour rating is typically about 10% higher than the continuous rating and is limited by the temperature rise in the motor.
Operating temperature. An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and ranges from the minimum ...
Newton's law of cooling. In the study of heat transfer, Newton's law of cooling is a physical law which states that the rate of heat loss of a body is directly proportional to the difference in the temperatures between the body and its environment. The law is frequently qualified to include the condition that the temperature difference is small ...
For the "temperate" climatic zones, the EN 590 standard defines six classes from A to F. In Central and Western Europe, the winter diesel (Winterdiesel, diesel d'hiver) must meet Class F conditions at least from the beginning of December to the end of February. During a transitional period (mostly October and April), a lower class must be met.
The most common fixed temperature point for electrically connected heat detectors is 58 °C (136 °F). Rate-of-rise heat detectors. Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature.